- Home
- Search Results
- Page 1 of 1
Search for: All records
-
Total Resources1
- Resource Type
-
0000000001000000
- More
- Availability
-
10
- Author / Contributor
- Filter by Author / Creator
-
-
Bacchetta, Matthew (1)
-
Chen, Jiawen (1)
-
Chen, Panpan (1)
-
Gavaudan, Olimpia (1)
-
Graney, Pamela_L (1)
-
Guenthart, Brandon_A (1)
-
Hudock, Maria_R (1)
-
Kaslow, Sarah_R (1)
-
Kim, Jinho (1)
-
Mir, Mohammad (1)
-
O'Neill, John_D (1)
-
Pinezich, Meghan_R (1)
-
Reimer, Jonathan_A (1)
-
Tavakol, Daniel_Naveed (1)
-
Van_Hassel, Julie (1)
-
Vunjak‐Novakovic, Gordana (1)
-
#Tyler Phillips, Kenneth E. (0)
-
#Willis, Ciara (0)
-
& Abreu-Ramos, E. D. (0)
-
& Abramson, C. I. (0)
-
- Filter by Editor
-
-
& Spizer, S. M. (0)
-
& . Spizer, S. (0)
-
& Ahn, J. (0)
-
& Bateiha, S. (0)
-
& Bosch, N. (0)
-
& Brennan K. (0)
-
& Brennan, K. (0)
-
& Chen, B. (0)
-
& Chen, Bodong (0)
-
& Drown, S. (0)
-
& Ferretti, F. (0)
-
& Higgins, A. (0)
-
& J. Peters (0)
-
& Kali, Y. (0)
-
& Ruiz-Arias, P.M. (0)
-
& S. Spitzer (0)
-
& Sahin. I. (0)
-
& Spitzer, S. (0)
-
& Spitzer, S.M. (0)
-
(submitted - in Review for IEEE ICASSP-2024) (0)
-
-
Have feedback or suggestions for a way to improve these results?
!
Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher.
Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?
Some links on this page may take you to non-federal websites. Their policies may differ from this site.
-
Abstract Pulmonary air leak is the most common complication of lung surgery, contributing to post‐operative morbidity in up to 60% of patients; yet, there is no reliable treatment. Available surgical sealants do not match the demanding deformation mechanics of lung tissue; and therefore, fail to seal air leak. To address this therapeutic gap, a sealant with structural and mechanical similarity to subpleural lung is designed, developed, and systematically evaluated. This “lung‐mimetic” sealant is a hydrofoam material that has alveolar‐like porous ultrastructure, lung‐like viscoelastic properties (adhesive, compressive, tensile), and lung extracellular matrix‐derived signals (matrikines) to support tissue repair. In biocompatibility testing, the lung‐mimetic sealant shows minimal cytotoxicity and immunogenicity in vitro. Human primary monocytes exposed to sealant matrikines in vitro upregulate key genes (MARCO, PDGFB, VEGF) known to correlate with pleural wound healing and tissue repair in vivo. In rat and swine models of pulmonary air leak, this lung‐mimetic sealant rapidly seals air leak and restores baseline lung mechanics. Altogether, these data indicate that the lung‐mimetic sealant can effectively seal pulmonary air leak and promote a favorable cellular response in vitro.more » « less
An official website of the United States government
